eCM Meeting Abstracts 2014, Collection 5
6th Symposium on Biodegradable Metals
Maratea, Italy, August 24-29 2014
Abstracts
All abstracts: click here to download all the abstracts in one file
Page 1: N Hort, B Wiese,M Wolff, T Ebel, P Maier
Stiffness of metals, alloys and components
Page 2: AJ Griebel, JE Schaffer
Cold-drawn ZM21 and WE43 wires exhibit exceptional strength and ductility
Page 3: G Szakács, CL Mendis, B Wiese, D Tolnai, A Stark, N Schell, KU Kainer, N Hort
In situ synchrotron radiation diffraction during solidification of Mg15Gd
Page 4: E Mostaed, M Hashempour, M Bestetti, A Tuissi, M Vedani
Investigation on Zinc based alloys for biodegradable stent applications
Page 5: HT Yang, ZH Wang, HF Li, YF Zheng, YW Li, R Li
In vitro study on novel Zn-ZnO composites with tunable degradation rate
Page 6: W Wu, L Petrini, L Altomare, S Faré, R Tremamunno, AG Demir, B Previtali, M Vedani, F Migliavacca
Experiments and numerical simulations to evaluate peeling properties of polymeric coatings for degradable Mg stents
Page 7: D Hong, D Chou, I Issaev, OI Velikokhatnyi, PN Kumta
Binder-jetting 3D printing (3DP) of customized patient specific craniofacial scaffolds of Fe-Mn based alloys
Page 8: T Li, HL Zhang, Y He, XT Wang
Effect of Sc addition on microstructure, mechanical properties and in vitro corrosion behaviour of biodegradable Mg-1.5Zn-0.6Zr (ZK21) alloy
Page 9: JG Zhou, P Gong, G Qu
Innovative biodegradable Zinc-based alloys for load-bearing biomedical implant applications
Page 10: O Hakimi, E Aghion
The prospects of EW62 Mg alloy as a structural material for biodegradable implants
Page 11: Z Xu, C Smith, S Yarmolenko, J Waterman, Y Chen, J Sankar
Comparative studies of mechanical, corrosion and cytotoxity of MgZnCa and MgZnCa-REs alloys
Page 12: M Wolff, JG Schaper, M Dahms, T Ebel, KU Kainer, T Klassen
Benefits and limitations of biodegradable Mg implants and parts, produced by MIM (Metal Injection Moulding)
Page 13: AG Demir, B Previtali
Submerged laser microcutting of Mg alloys with ns pulsed green laser for biodegradable stents
Page 14: Z Liu, F Feyerabend, R Willumeit
Mechanical properties of extruded antimicrobial Mg-Ag alloys
Page 15: M Inoue, H Ueda, K Hanada
Precise extrusion processing of Magnesium alloy small tube for biodegradable stent application
Page 16: J Wu, P Saha, B Lee, J Waterman, TW Gilbert, PN Kumta
Evaluation of magnesium alloys for tracheal stent application
Page 17: L Mao, M Elitas, J Zhang, J Niu, Y Shi, R Fan, G Yuan
Biodegradable Mg alloy with modified nanoscale surface for stent applications
Page 18: IS Berglund, B Mobley, MA Wener, HB Henderson, MV Manuel
The effect of hot rolling on the microstructure and degradation behaviour of a Mg-Ca-Sr alloy
Page 19: D-T Chou, D Hong, P Saha, B Lee, Y Chen, Z Xu, PN Kumta
Synthesis and characterization of biodegradable magnesium-yttrium based alloys for musculoskeletal load-bearing medical implants
Page 20: E Mostaed, M Hashempour, A Fabrizi, D Dellasega, M Bestetti, F Bonollo, M Vedani
Mechanical and corrosion properties of UFG Mg alloys
Page 21: N Li, SM Zheng, JR Peng, YF Zheng, LQ Ruan
In vitro degradation of pure magnesium and WE43 alloy in human bile
Page 22: NA Agha, F Feyerabend, B Mihailova, S Heidrich, R Willumeit
Magnesium corrosion under physiological conditions
Page 23: BY Peng, YJ Chen, ZG Xu, S Yarmolenko
Influence of deformation on the corrosion and cytocompatibility of biodegradable Mg alloys
Page 24: M Costantino, B Luthringer, R Willumeit
Inflammatory response to magnesium based biodegradable implant materials
Page 25: SC Cifuentes, L Saldaña, V Lorenzo, M Lieblich, R Benavente, JL González-Carrasco
Suitability of novel PLA/Magnesium composites for biodegradable implants
Page 26: ZJ Zhai, GW Liu, L Ren, Y Li, HW Li, ZX Ouyang, XQ Liu, K Yang, XH Qu, KR Dai
Metallic magnesium degradation products inhibit human breast cancer bone metastasis via multiple signalling pathways
Page 27: LL Wu, BJC Luthringer, F Feyerabend, AF Schilling, R Willumeit
Effects of extracellular magnesium extracts on the proliferation and differentiation of human osteoblast-osteoclast co-cultures
Page 28: A Burmester, F Feyerabend, R Willumeit
Behavior of bone cells due to contact to magnesium implant material
Page 29: R Willumeit-Römer, H-P Wendel, B Mihailova, N Ahmad Agha, F Feyerabend
How does blood contact change Magnesium degradation?
Page 30: S Yu, Z Yu, Q Zhang, J Niu, J Han, C Liu
Preparation and antibacterial properties of Ag-loaded porous coatings on the Mg-3Nd-4Y-0.5Zr alloy by two-step electrochemical method
Page 31: YJ Chen, ZG Xu, S Yarmolenko, C Smith, J Waterman, J Sankar
Excellent mechanical properties and cytocompatibility of non-rare earth Mg-Zn-based alloys
Page 32: F Mert, F Muhaffel, H Çimenoğlu
Characterization and wear behaviour of MAO on high pressure die cast AM50 magnesium alloy
Page 33: K Hanada, K Matsuzaki
Development of long-fine WE43 wire for biodegradable medical applications
Page 34: E Mouzou, C Paternoster, R Tolouei, M Sikora-Jasinska, S Turgeon, D Mantovani
A comparative study of the degradation of pure Fe and Fe-20Mn-1.2C alloy in modified Hanks’ solution for biodegradable cardiovascular devices
Page 35: A Gil-Santos, G Szakacs, N Hort, O Van der Biest
Thermodynamic calculation and experimental studies of phase relations in the Mg-Si-Ca-Sr system for degradable biomaterials
Page 36: P Maier, R Erdmann, R Tesch, G Szakács, N Hort
Influence of corrosion on mechanical properties of Mg5Gd wire
Page 37: WD Muelle, H Hornberger
Cyclic voltammetry for prediction of degradation of resorbable metallic biomaterials: possibilities and limitations
Page 38: NA Shaharom, H Hermawan
Electrochemical study of Mg-0.6Ca alloy under a constant strain condition
Page 39: P Quadbeck, C Redlich, H Göhler, B Kieback
Methodical screening of corrosion mechanisms of iron alloys for the manipulation of degradation rates
Page 40: A Eliezer, C Gasqueres, KS Lips, L Heimann, C Sattig, D Zukowski, E Dingeldein, T Batsch
Bioactive coatings as a key for advanced biomedical applications
Page 41: Y Su, C Lu, J Lian, G Li
Corrosion protection of biocompatible HA/CaP composite coating on AZ60 alloy
Page 42: I Marco, O van der Biest, F Feyerabend, R Willumeit
Comparison of the degradation behaviour of binary Mg-Ag and Mg-Gd alloys in PBS and in physiological conditions
Page 43: T Hassel, M Bauer, P Hoyer, AJ Patil, E Beniash, F-W Bach, HJ Maier
Study of magnesium fluoride and self-assembled organosilane coatings of AZ31 and MgCa0.8 alloys
Page 44: C Schille, S Kluba, M Krimmel, T Wolfram, L Gabele, J Geis-Gerstorfer
Influence of different surface modifications of the magnesium alloy WE43 on the electrochemical behaviour
Page 45: M Bartosch, H Peters, DO h-Ici, A Körner, P Zaslansky, B Schmitt, F Witte, F Berger
Different approaches for in vivo testing of absorbable metals in blood vessels
Page 46: AG Demir, TB Taketa, R Tolouei, V Furlan, C Paternoster, MM Beppu, D Mantovani, B Previtali
Page 47: R Kotoka, G Ramakrishna, S Yarmolenko, D Pai, J Sankar
Combinatorial corrosion studies of Mg-Zn alloy coatings
Page 48: M Zhou, N Li, YF Zheng, LQ Ruan
In vitro study on the modified ZK60 alloy with the addition of 0.2wt.% Ca
Page 49: F Cecchinato,NNA Agha, A Martinez, B Luthringer, R Jimbo, A Wennerberg, F Feyerabend, R Willumeit
Influence of binary magnesium alloys corrosion on morphology and adhesion of human undifferentiated cells
Page 50: YH Wu, N Li, Y Liu, YF Zheng, P He, M Li, Y Zhang
In vitro study on biodegradable Mg-1Ca-2Sr-XZn (X=2, 4, 6) alloys
Page 51: H Schluter, M Omidi, A Burmester, R Willumeit
Application of proteomics for investigating the impact of magnesium implants on bone tissue
Page 52: J Hofstetter, E Martinelli, A Weinberg, M Becker, B Mingler, PJ Uggowitzer, JF Löffler
In vitro and in vivo degradation of ultrahigh-pure magnesium
Page 53: J Reifenrath, L Wolters, C Roessig, JM Seitz, P Helmecke, A Meyer-Lindenberg, N Angrisani
Are biodegradable Mg-based implant materials suitable for the use in osteosynthesis systems?
Page 54: GJ Dias, J Walker
Rational approach for evaluating Mg alloys for their biocompatibility
Page 55: C Liu, P He, P Wan, LL Tan, Y Zhang, K Yang
Study on in vitro biocompatibility and macrophage phagocytosis of Mg17Al12 in
Mg-Al-Zn alloys
Page 56: ZJ Zhai, GW Liu, LL Tan, Y Li, HW Li, ZX Ouyang, XQ Liu, K Yang, XH Qu, KR Dai
Effect of Mg-2Sr alloys on Fracture Healing in Osteoporotic Rats, via SMAD1/5/8 Signaling
Page 57: J Niu, D Laipple, F Feyerabend, G Yuan, F Witte
In vitro study on the corrosion protective effect of cells adhesion on biodegradable Mg-Nd-Zn-Zr alloy
Page 58: BJC Luthringer, R Willumeit
Effect of magnesium extract on osteoblastic progenitor cells differentiation
Page 59: N Zhao, D Zhu
Endothelial growth on fluoride and collagen coated magnesium alloys
Page 60: JAM Maier, S Castiglioni, C Cappadone, G Farruggia, S Iotti
Magnesium alloys in implantology: the effects of high concentrations of magnesium on human osteoblasts
Page 61: N Zhao, J Ma, D Zhu
In vitro biocompatibility of novel magnesium-rare earth based stent materials
Page 62: Z Zhen, L Yang, TF Xi, YF Zheng
Proteomics study of mouse fibroblasts exposed to biodegradable pure magnesium
Page 63: M Xiong, X Guan, F Zeng, B Xu, J Niu, J Zhang, C Chen, J Pei, G Yuan
In vivo characterization of brushite coated Mg–Nd–Zn–Zr alloy for mandible bone repairing applications
Page 64: S Galli, G Szakács, F Lukáč, M Vlček, R Jimbo, Y Naito, A Wennerberg, J Herzen, J Hammel, R Willumeit
Osseointegration of resorbable magnesium screws – A SRμCT Study
Page 65: F Alvarez, RM Lozano Puerto, BT Pérez-Maceda, CA Grillo, MA Fernández Lorenzo
Effect of Mg particles on MC3T3-E1 and J774 cellular cycle. Influence of fluoride treatment
Page 66: TF Xi, T Huang, BZ Gao, SY Kuang, ZH Wang, LN Wei
The electrophysiological effects of magnesium-based biomaterials on nerve cells
Page 67: CA Grillo, F Alvarez, M Fernández Lorenzo de Mele
Cytotoxicity evaluation of ions released by a Mg-based alloy (ZEK100) in vitro: Comparison of the results obtained with different assays
Page 68: J Ma, N Zhao, D Zhu
Novel magnesium-based stent biomaterials with anti-corrosion and drug-eluting coatings
Page 69: AH Martínez-Sánchez, F Feyerabend, B Luthringer, R Willumeit
Effect of magnesium extracts on the chondrogenic differentiation of HUCPV cells
Page 70: SC Cifuentes, R Gavilán, A San Román, M Lieblich, R Benavente, JL González-Carrasco
Effect of magnesium particle shape on in-vitro degradation kinetics of novel PLA/Magnesium composites
Page 71: A Witecka, A Yamamoto, W Swieszkowski
Influence of SaOS-2 cells on corrosion behaviour of cast ZM21 magnesium alloy
Page 72: M Omidi, A Gasser, E Hesse, A Weinberg, R Willumeit, H Schlüter
Proteomic approaches for studying bone tissue sections
Page 73: NS Fagali, CA Grillo, S Puntarulo, MA Fernández Lorenzo
Evaluation of cell damage produced by Fe ions released as degradation products of biomaterials. Influence of pH changes
Page 74: D Zhao, S Huang, L Qin, Y Li, B Wang
The application of biodegradable magnesium screw in hip surgery
Page 75: J Eichler, F Amerstorfer, T Kraus, S Fischerauer, E Martinelli, PJ Uggowitzer, J Löffler, A Weinberg
Long-term in vivo degradation behaviour of Mg alloys WZ21 and ZX50 – A micro CT study
Page 76: S Zhang, J Liu, J Yan, Y Chen, C Zhao, Y Zhang, M Jiang, H Xu, J Ni, X Zhang
In vivo degradation and biocompatibility of linear cutter staples made of high purity magnesium
Page 77: SY Cho, KJ Han, HK Seok
Preclinical and clinical study of Mg-Ca-Zn alloy
Page 78: A Chaya, S Yoshizawa, N Myers, K Verdelis, DT Chou, PN Kumta, C Sfeir
Degradable magnesium plates and screws for bone fracture fixation
Page 79: AJ Brown, SH Zaky, HL Ray, C Sfeir
Magnesium/PLGA composite scaffolds for improved bone regeneration
Page 80: JE Schaffer, AJ Griebel
Embolic risk mitigation in absorbable implants by composite design
Page 81: MF Ulum, NS Murni, D Noviana, H Hermawan
Peri-implant assessment of Fe-HA composite for temporary bone implants
Page 82: E Marukawa, M Tamai, Y Takahashi, I Hatakeyama, M Sato, Y Higuchi, H Harada, K Omura
Comparison of magnesium alloy and poly-L-lactide screws as degradable implant in canine fracture model
Page 83: H-S Han, JHL Han, Y-C Kim, H-K Seok, JW Lee, S-J Yang
The evaluation of histological methods for biodegradable magnesium
Page 84: Y Li, LN Liu, P Wan, ZJ Zhai, ZA Zhu, DG Yu, K Yang, XH Qu, KR Dai
Biodegradable Mg-Cu alloy implants with antibacterial and osteostimulatory activity for the treatment of osteomyelitis: in vitro and in vivo evaluation
Page 85: ZJ Zhai, XH Qu, HW Li, K Yang, P Wan, L Tan, ZX Ouyang, XQ Liu, KR Dai
The effect of metallic magnesium degradation products on osteoclast-induced osteolysis and attenuation of NF-κB and NFATc1 signaling
Page 86: E Martinelli, J Eichler, T Kraus, S Fischerauer, PJ Uggowitzer, JF Löffler, A Weinberg
Ultra-pure magnesium alloys for use as biodegradable paediatric osteosynthetic material
Page 87: H Nygren, G Kjeller, P Malmberg, S Gustafsson
Increase of compact bone mass is the endpoint effect of MgO implants
Page 88: J Wang, F Witte, T Xi, Y Zheng, K Yang, Y Yang, D Zhao, J Meng, Y Li, W Li, L Qin
Recommendation for modification of current cytotoxicity testing standards for biodegradable magnesium materials
All abstracts: click here to download all the abstracts in one file